Escient FireBall H-40 Remote control Manuel d'utilisateur Page 110

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 145
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 109
110
TheaterTouch Designer
CAPTURING IR CODES WITH AN IR-PRO LEARNING DEVICE
The first step in capturing IR codes with an IR-PRO learning device is to align the donor remote correctly. This
step is very important, as it allows the Infrared Library Manager to determine the carrier frequency of the donor
remote.
1. Connect the IR-PRO to a free USB port on your PC.
2. Select the Capture tab.
3. Choose the Enable Capture button.
4. Choose the Align button.
5. When the device is in Align mode, you will see the
following on the Capture tab:
6. Hold down any key on the donor remote, and move
it around in front of the capture unit until the signal
strength meter turns red and the frequency reading
is stable.
Once the remote is properly aligned:
1. Select the "Learn" button. The Infrared Library
Manager will automatically highlight the first func
-
tion in the current library without an associated IR
code.
2. If you want to learn another function, select it in the
function list. Your Capture tab should now look like
this:
3. Press and hold down the requested function ("Play"
in this case) until the Infrared Library Manager
learns the code and moves on to the next code.
Important: Once you have the donor remote aligned, try to avoid moving it while capturing codes. If the remote
does move out of position, select the Align button and go through the alignment procedure again. If you are having
problems communicating with your USB device, see Troubleshooting Communications Problems - Chapter 12.
Vue de la page 109
1 2 ... 105 106 107 108 109 110 111 112 113 114 115 ... 144 145

Commentaires sur ces manuels

Pas de commentaire